id: PG-07
category: compute
title: Fence before you evacuate
situation: >-
  A compute is unreachable and users report their instances down. Nova still shows them `ACTIVE`: it cannot
  know whether the host is dead or only cut off from the control plane.

diagram:
  type: chain
  caption: The order that makes evacuation safe
  nodes:
    - step: "1"
      label: Confirm out of band
      sub: BMC power state, switch port, storage clients
      tone: ok
    - step: "2"
      label: Fence
      sub: Power off. Failing that, isolate every port
      tone: stop
    - step: "3"
      label: Disable the service
      sub: Force it down if needed, only now
      tone: warn
    - step: "4"
      label: Evacuate
      sub: Rebuilds each instance on another host
      tone: stop
  note: >-
    Local ephemeral disks are rebuilt from the image: their content is lost. From microversion 2.95 an
    evacuated instance stays stopped.

checks:
  - label: Nova's view of the host
    hint: openstack compute service list --host <host> --long
  - label: Instances on the host
    hint: openstack server list --all-projects --host <host> --long
  - label: Does the host answer at all?
    hint: "ssh <host> uptime (if it answers, it is NOT dead: stop)"
  - label: Out-of-band power state
    hint: "BMC, iDRAC, iLO: the authoritative source"

caution:
  - level: destructive
    text: >-
      Evacuating a host that still runs its instances gives each volume two writers. The recovery is then
      worse than the outage.
  - level: know
    text: >-
      Automation that evacuates on a lost heartbeat must fence first, or it will one day destroy the workload
      it was meant to save.

lesson: The precondition for evacuation is fencing, not a missing heartbeat.

runbook:
  path: recovery/compute-host-failure-fence-before-evacuate.md
  status: lab-verified
  release: "2026.1"

scope: >-
  Derived from a real incident and lab-verified on OpenStack 2026.1 (Kolla-Ansible, ML2/OVS, local disks and
  Cinder LVM). Fencing through IPMI or the switch, the Ceph blocklist and evacuation with shared instance
  storage were not run on the lab. Evacuation semantics for local storage and the behaviour of a returning
  host should be checked against the Nova documentation of your release. Assumes the libvirt driver.

linkedin:
  title: "Fence before you evacuate. Always."
  caption: |
    A compute host stops answering. The instances on it are down. The pressure to run "server evacuate" is immediate.

    But Nova cannot tell a dead host from an unreachable one. If the host is only cut off from the control plane, its instances may still be running, and still writing. Evacuate now and each volume gets two writers.

    The order that makes it safe:
    1. Confirm out of band (BMC, switch port, storage side)
    2. Fence: power off, or failing that isolate every port
    3. Disable the service, and force it down if needed, only now
    4. Evacuate

    The same goes for auto-evacuation tooling: if it reacts to a lost heartbeat without fencing, it will one day destroy the workload it was meant to save.

    The precondition for evacuation is fencing, not a missing heartbeat.
  hashtags: [OpenStack, Nova, HighAvailability, DisasterRecovery, CloudOperations, OzarLand]