id: PG-44
category: production-operations
title: Logs do not line up?
situation: >-
  Following one incident across hosts, the lines of one compute appear minutes before the events that caused
  them. Its clock has drifted, and nothing alerts.

diagram:
  type: compare
  caption: A compute a few minutes off (lab, 300 s back)
  columns:
    - kicker: What it does not break
      title: The platform
      icon: server
      tone: mute
      points:
        - "`nova-compute` stays up, agents alive"
        - New instances boot
        - No time warning in its logs
      verdict: Nothing fails
    - kicker: What it breaks
      title: Your investigation
      icon: search
      tone: warn
      points:
        - Its logs carry its own wrong clock
        - A timeline across hosts is in the wrong order
      verdict: Conclusions mislead
  note: >-
    Not covered, and likely more serious: a drift on a controller (tokens, Galera, RabbitMQ), or a larger
    offset.

checks:
  - label: Is the clock synchronised?
    hint: timedatectl
  - label: Compare every host, in one run
    hint: "ansible -i <inventory> all -m command -a 'date -u +%s'"
  - label: With chrony
    hint: chronyc tracking
  - label: Why the host lost its time
    hint: "service stopped, no or unreachable server, clock set by hand"

caution:
  - level: state-changing
    text: >-
      `timedatectl timesync-status` can start a stopped timesyncd, which steps the clock. Measure the offset
      first.
  - level: state-changing
    text: >-
      Starting time synchronisation makes the clock jump by the offset. The log timestamps of that host jump
      with it.

lesson: Before trusting a timeline built from several hosts, compare their clocks.

runbook:
  path: diagnostics/compute-clock-skew.md
  status: lab-verified
  release: "2026.1"
  also:
    - logs/time-sync-chrony-and-clock-skew.md

scope: >-
  Observed on one lab build: OpenStack 2026.1, Kolla-Ansible, ML2/OVS, Ubuntu 24.04 with systemd-timesyncd, a
  300 s backward drift on one compute for a few minutes. chrony was not run. Not tested: a drift on a
  controller, a forward drift, a larger or longer offset, TLS certificate validity, OVN. Do not assume this
  memo applies to them. With Nova's database service group driver, liveness is recorded on the controllers,
  with their clocks, which is why Nova and Neutron do not complain.

linkedin:
  title: "The logs of one host do not line up: check its clock before your theory"
  caption: |
    You are rebuilding an incident from the logs of several hosts. On one compute, the lines appear minutes before the events that caused them. The story stops making sense.

    Before building a theory around it, compare the clocks.

    A compute whose clock is a few minutes off keeps working. On a lab, with 300 seconds of drift: nova-compute up, agents alive, new instances booting, no time-related warning in its logs. Nothing fails and nothing alerts. The only thing it breaks is your investigation: its logs carry its own wrong time.

    One detail worth knowing: on a host where systemd-timesyncd is only stopped, running timedatectl timesync-status starts it, which steps the clock and erases the offset you wanted to measure. Compare the clocks first.

    A drift on a controller is another story, likely a more serious one, and not tested here.
  hashtags: [OpenStack, Observability, IncidentResponse, SRE, CloudOperations, OzarLand]