Conductor or scheduler down? Operational lesson: With the conductor gone, every compute looks down. Nothing is wrong on the hosts.

Operational lesson. With the conductor gone, every compute looks down. Nothing is wrong on the hosts.

The memo as text

Situation. Nova does not fail at once, and not everywhere. Some requests wait in a queue and finish later, some time out. Running instances do not notice.

First checks (read-only):

  1. Services, as Nova sees them: openstack compute service list
  2. Do their queues have consumers?: rabbitmqctl list_queues -p <vhost> name messages consumers
  3. Their own logs: nova-conductor.log, nova-scheduler.log
  4. Builds still waiting: openstack server list --all-projects --status BUILD

Think before acting:

  • ⛔ Avoid. Deleting instances while the conductor is down. Computes are reported down, so each delete is a local delete.
  • ⛔ Avoid. Restarting Nova services while RabbitMQ is partitioned or blocked. They reconnect, and wait again.

Go deeper

This memo is a memory aid. The procedure, with every command, its risk warning and its limits, is in the runbook:

Where this holds. Written from the Nova 2026.1 source and lab-verified with Kolla-Ansible. The 60 s is rpc_response_timeout, Nova's default. Builds that timed out are not retried: their owners build again. A start, stop or reboot sent while the conductor was down can leave a task state that nothing clears. Applies when every copy of the service is down, in a single cell. Queued builds survive with quorum queues and RabbitMQ staying up; a RabbitMQ reset drops them.

LinkedIn kit

nova-conductor and nova-scheduler live on the controllers. When every copy of one of them is down, Nova does not fail at once, and not everywhere.

With the conductor down:
→ new builds stay in BUILD, and finish by themselves when it is back
→ within a minute every compute is reported "down", while its instances keep running
→ start, stop and reboot time out

With the scheduler down:
→ new builds fail after about a minute, and land in ERROR in cell0, with no host
→ start, stop and reboot still work

In both cases API reads work, and running instances notice nothing.

The trap is the wall of "down" computes. nova-compute has no database access of its own: its heartbeat goes through the conductor. Nothing is wrong on the hosts. And deleting an instance at that moment is a local delete.

Runbook: https://github.com/OzarLand/ozarland-academy/blob/main/docs/runbooks/recovery/nova-conductor-or-scheduler-down-what-still-works.md
More memos: https://github.com/OzarLand/ozarland-academy/tree/main/docs/production

#OpenStack #Nova #ControlPlane #IncidentResponse #CloudOperations #OzarLand

Source: conductor-or-scheduler-down.yml. Found an error, or does your platform behave differently? Open an issue or see CONTRIBUTING.